Environment Monitoring System AC & DC Power Monitors
Power Relays & Sensors compatible with ENVIROMUX-2D, ENVIROMUX-5D and ENVIROMUX-16D
AC & DC Monitors
AC & DC Voltage & Current Monitor
ENVIROMUX-ACDCLM
The AC & DC Voltage & Current Monitor measures and reports AC and DC voltage, and reports AC and DC current measured with attached Hall-Effect transducers (sold separately) to the ENVIROMUX-2D/5D/16D unit.
- Reports AC voltage, AC current, DC voltage and DC current.
- Current measurements require Hall-Effect transducers (sold separately).
- Polling rate: 1Sa/s.
- Common applications include: electrical systems, power equipment, battery monitoring, generators, remote sites, controlled environment vaults (CEVs), building automation, data center, cabinets, telecom, substations, storage power supplies, communication huts, indoor/outdoor lighting, power distribution, and medical and test equipment.
- AC voltage 2-pin terminal block
- 0 to 240VAC 600V isolated
- 0.25VAC resolution
- Accuracy
- 0 to 220VAC: 2.5VAC accuracy
- 220 to 240VAC: 5.0VAC accuracy
- DC voltage 2-pin terminal block
- -60 to +60V DC non-isolated
- 0.12VDC resolution
- 1.2VDC accuracy
- One rectifying Hall Effect 4-pin transducer interface for measuring AC current
- 0.2% resolution
- Accuracy and range are transducer-dependent (sold separately).
- One non-rectifying Hall Effect 4-pin transducer interface for measuring DC current
- 0.2% resolution
- Accuracy and range are transducer-dependent (sold separately).
- Supports CAT5/5e/6 cable up to 1,000 ft (305 m).
- Dimensions WxDxH (in): 6.2x2.3x1.6 (158x58x41 mm).
- Current consumption: 8mA @ 5VDC, 66mA @ 12VDC.
- Powered by ENVIROMUX-2D/5D/16D.
- Regulatory approvals: CE, RoHS.
- Compatible with ENVIROMUX-FSC Fiber Converter/Extender.
- Use to extend the monitor up to 1.2 miles (2km) from the ENVIROMUX unit.
DC Line Monitor
ENVIROMUX-DCLM-6
The DC Line Monitor measures DC voltage and reports DC current measured with attached Hall-Effect transducers (sold separately) to the ENVIROMUX-2D/5D/16D unit.
- Reports DC voltage and DC current.
- Current measurements require Hall-Effect transducers (sold separately).
- Polling rate: 1Sa/s.
- Six 2-pin terminal blocks for measuring DC voltage
- Non-isolated -60 to +60V DC
- 0.12VDC resolution
- 1.2VDC accuracy
- Six non-rectifying Hall Effect 4-pin transducer interfaces for measuring DC current
- 0.2% resolution
- Accuracy and range are transducer-dependent (sold separately).
- Supports CAT5/5e/6 cable up to 1,000 ft (305 m) (18-24 AWG).
- Current consumption: 190mA @ 12VDC.
- Powered by ENVIROMUX-2D/5D/16D.
- The ENVIROMUX-DCLM-6 may require more power than the RJ45 sensor ports can supply on the ENVIROMUX-2D/15D/16D.
- Refer to page 2 of the manual to determine if the optional PWR-SPLY-12V1A power supply is necessary for your configuration.
- The ENVIROMUX-DCLM-6 may require more power than the RJ45 sensor ports can supply on the ENVIROMUX-2D/15D/16D.
- Dimensions WxDxH (in): 6.82x3x1.71" (173x76x43 mm).
- Regulatory approvals: CE, RoHS.
- Compatible with ENVIROMUX-FSC Fiber Converter/Extender.
- Use to extend sensor up to 1.2 miles (2km) from the ENVIROMUX unit.
AC Power Monitor with Relay
- Reports AC Voltage, Frequency, Power, and Current.
- Monitors Power from one AC inlet to one AC outlet, between 50~250VAC and 47~63Hz.
- Monitors the number of swells, sags, and spikes.
- Monitors swell and sag duration of 0.1 second to 1 minute.
- Includes Relay with configurable disconnect settings: threshold reboot, or manual reboot.
- Accuracy
- Voltage accuracy: ± 1%
- Frequency accuracy: ± 1%
- Current accuracy: ± 1%
- Outlet Max load rating (continuous):
- ENVIROMUX-ACLM-P18 (US/Canada): 18A rated load, 20A maximum.
- ENVIROMUX-ACLM-P12 (US/Canada): 12A rated load, 15A maximum.
- ENVIROMUX-ACLM-P8 (Euro/UK): 8A rated load, 10A maximum.
- Capable of measuring current surges from 300 mA to 20A.
- User defined minimum and maximum voltage and power thresholds.
- Capable of detecting user selected spike events with a peak greater than 50V, 250V, 500V, or 1KV.
- Cables included:
- ENVIROMUX-ACLM-P12/8: one country-specific IEC 320 C13 line cord, and one IEC 320 C14 to IEC 320 C13 cord set for connection to AC load.
- ENVIROMUX-ACLM-P18: one L6-20r to IEC 320 C20, and one L6-20p to IEC 320 C19.
- Supports CAT5/5e/6 cable up to 1,000 ft. (305 m).
- ENVIROMUX-2D/5D: supports CAT5/5e/6 cable up to 750 ft (229 m).
- Dimensions (WxDxH) in:
- ENVIROMUX-ACLM-P12/8: 7.0x5.5x1.65 (178x140x42 mm).
- ENVIROMUX-ACLM-P18: 7.0x6.5x1.65 (178x165x42 mm).
- Weight: 1.6 lbs (726 g).
- Current consumption: 13mA @ 5VDC, 125mA @ 12VDC.
- Powered by ENVIROMUX-2D/5D/16D.
- Regulatory approvals: CE, RoHS
- Compatible with ENVIROMUX-FSC Fiber Converter/Extender.
- Use to extend sensor up to 1.2 miles (2 km) from the ENVIROMUX unit.
AC Dual Voltage Monitor
ENVIROMUX-ACLM-V
- Reports AC Voltage and Frequency.
- Monitors AC voltage and frequency on two AC inlets between 50~250VAC and 47~63Hz.
- Monitors the number of swells, sags, and spikes.
- Voltage accuracy: ± 1%
- Frequency accuracy: ± 1%
- User defined minimum and maximum voltage thresholds.
- Capable of detecting user selected spike events with a peak greater than 50V, 250V, 500V, or 1KV.
- Supports CAT5/5e/6 cable up to 1,000 ft. (305 m).
- Current consumption: 70mA @ 12VDC.
- Powered by ENVIROMUX-2D/5D/16D.
- Regulatory approvals: CE, RoHS
- Compatible with ENVIROMUX-FSC Fiber Converter/Extender.
- Use to extend sensor up to 1.2 miles (2 km) from the ENVIROMUX unit.
DC Voltage Monitor
ENVIROMUX-S60VDC
- Monitors up to two DC voltages: -60VDC ~ 0VDC or 0VDC ~ 60VDC
- Accuracy: ± 100mV ± 1% reading
- Connector: Screw Terminal, 5-position
- Supports CAT5/5e/6 cable up to 1,000 ft. (305 m)
- Includes Mounting Hardware
- Operating temperature: 32 to 158°F (0 to 70°C).
- Current consumption: 30mA @ 12VDC.
- Powered by ENVIROMUX-2D/5D/16D.
- Regulatory approvals: CE, RoHS
- Compatible with ENVIROMUX-FSC Fiber Converter/Extender.
- Use to extend sensor up to 1.2 miles (2 km) from the ENVIROMUX unit.