ENVIROMUX-STS
 |
 ENVIROMUX-SHS
 |
- Applications from 0°C to 50°C (32°F to 122°F).
- Accurate to within ±0.5°C (±0.9°F).
- High resistance to external influences on the cable due to digital output signal.
- Re-calibration is not necessary after initial set-up.
- Includes mounting hardware.
- RJ45 connector.
- Supports CAT5/5e/6 cable up to 305 meters (not included)
- Powered by ENVIROMUX-SEMS-16 or SERIMUX-S-x.
- Regulatory approvals: CE, RoHS
- Compatible with ENVIROMUX-SEMS-16
and SERIMUX-S-x only.
|
- Applications from 20% to 80% relative humidity at temperatures between
0°C to 40°C (32°F and 104°F).
- Accurate to within ±5% relative humidity.
- High resistance to external influences on the cable due to digital output signal.
- Re-calibration is not necessary after initial set-up.
- Includes mounting hardware.
- RJ45 connector.
- Supports CAT5/5e/6 cable up to 305 meters (not included)
- Powered by ENVIROMUX-SEMS-16 or SERIMUX-S-x.
- Regulatory approvals: CE, RoHS
- Compatible with ENVIROMUX-SEMS-16
and SERIMUX-S-x only. |

ENVIROMUX-STHS
 |

ENVIROMUX-STHS-99
 |
- Applications from 0°C to 50°C (32°F to 122°F) and 20% to 80% relative humidity.
- Accurate to within ±0.5°C (±0.9°F) and ±5% relative humidity.
- High resistance to external influences on the cable due to digital output signal.
- Re-calibration is not necessary after initial set-up.
- Includes mounting hardware.
- RJ45 connector.
- Supports CAT5/5e/6 cable up to 305 meters (not included)
- Powered by ENVIROMUX-SEMS-16 or SERIMUX-S-x.
- Regulatory approvals: CE, RoHS
- Compatible with ENVIROMUX-SEMS-16
and SERIMUX-S-x only. |
- Applications from 0°C to 50°C
(32°F to 122°F)
- Accurate to within ±1°C (±2°F)
- 20% to 80% relative humidity, ±3%
- 10% to 90% relative humidity, ±4%
- 0% to 99% relative humidity, ±5%
- High resistance to external influences on the cable due to digital output signal.
- Re-calibration is not necessary after initial set-up.
- Includes mounting hardware.
- RJ45 connector.
- Supports CAT5/5e/6 cable up to 305 meters (not included)
- Powered by ENVIROMUX-SEMS-16 or SERIMUX-S-x.
- Regulatory approvals: CE, RoHS
- Compatible with ENVIROMUX-SEMS-16
and SERIMUX-S-x only. |

ENVIROMUX-SHS-PLT |

ENVIROMUX-STHS-PLT-xxx |
- NIST certified accurate to within ±1% from 10% to 80% relative humidity at 25°C to 35°C (77°F to 95°F).
- Two-point field calibration.
- Output: 4-20mA DC = 0% to 100% RH.
- Requires the ENVIROMUX-S420MA to operate.
|
- Available temperature ranges:
- -20°F to 140°F (-28°C
to 60°C).
- -6°C to 48°C (20°F to 120°F).
- -1°C to 82°C (30°F to 180°F).
- Temperature accurate to within ± 1.50%.
- NIST certified accurate to within ±1% from 10% to 80% relative humidity at 25°C to 35°C (77°F to 95°F).
- Uses a platinum RTD for precision temperature compensation.
- Sensing element: 1000W platinum; 2 lead resistance thermometer, .00385 TCR
- Two-point field calibration.
- Output: 4-20mA DC = 0% to 100% RH.
- Requires the ENVIROMUX-S420MA to operate.
|
 ENVIROMUX-LDSx-y

Application Note: Detect Conductive Liquids in a Server Room
| ENVIROMUX-SDS |
- For warning of flooding.
- Detects liquid depth >0.25 cm.
- Minimum puddle: 1.53 cm diameter.
- 100% waterproof electronics.
- Detects any liquid, except deionized water.
- RJ45 connector.
- Supports CAT5/5e/6 cable up to 305 meters (not included).
- Supports water sensor cable lengths from 0.3 to 305 meters.
- Supports 2-wire cable lengths from 1.52 to 30.5 meters.
- Powered by ENVIROMUX-SEMS-16 or SERIMUX-S-x.
- Regulatory approvals: CE, RoHS
- Compatible with ENVIROMUX-SEMS-16 and SERIMUX-S-x only.
|
- For warning of smoke.
- Built-in 57° C (135° F) thermal heat sensor.
- Includes mounting hardware.
- Connect to RJ45 or digital input sensor ports.
- Supports CAT5/5e/6 UTP or STP cables.
- Photoelectric smoke detector.
- Screw terminal
- To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
- Maximum cable length: 305 meters
- Powered by ENVIROMUX-SEMS-16.
- Regulatory approvals: UL
|
 ENVIROMUX-AFM
 |
 ENVIROMUX-CMD
|
- Reliable mechanical solution for monitoring
air flow.
- Reacts to any condition causing insufficient flow of air such as malfunctioning cooling fan, increased friction, or physical blockage.
- Can be used for direct monitoring of a cooling fan.
- Dimensions WxDxH (mm): 34x17.5x7.5
- Switch contact is closed when air flow is >2.5 m/s.
- Connection: 2x single strand AWG26, length 0.5 m.
- Regulatory approvals: RoHS
|
- Continuous air monitoring.
- Pre-set alarm points alert at:
- 70 ppm after 60 to 240 minutes
- 150 ppm after 10 to 50 minutes
- 400 ppm after 4 to 15 minutes
- Flush or surface mount.
- Test functionality of electrochemical CO sensing cell.
- Connect to RJ45 or digital input sensor ports.
- Screw terminal
- To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
- LED indicators for operation status and system test.
- Powered by ENVIROMUX-SEMS-16.
- Regulatory approvals: UL
|
 ENVIROMUX-AV-x w/Converter ENVIROMUX-AV-SB2

Application Note: Measure Air Velocity in a Server Room
|
 ENVIROMUX-2W-xx
|
- Reliable sensor for measurement of air velocity.
- Air velocity sensor requires converter unit ENVIROMUX-AV-SB2
- Connect up to two air velocity sensors.
- Includes mounting hardware.
- Locate up to 305 meters from the ENVIROMUX-SEMS-16 via CAT5/5e/6 cable(not included).
- Connectors:
- Two RJ11 connectors for air velocity sensor
- RJ45 connector for ENVIROMUX-SEMS-16.
- Flow range: 0-3m/s ±10% accuracy at 77°F (25°C) 1 atmosphere.
- Dust resistant design.
- Sensor cable available in lengths: 0.9, 2.1, 3.0, 7.6, 15.2, and 30.5 meters.
- Powered by ENVIROMUX-SEMS-16.
- Regulatory approvals: RoHS.
- Requires the ENVIROMUX-SEMS-16 to operate.
|
- 2-wire sensor cable.
- Use to connect dry contact sensors to the ENVIROMUX-SEMS-16.
- Available lengths (m): .9/1.8/3/7.6/15.2/30.5
- Regulatory approvals: RoHS, UL
|
|

ENVIROMUX-S420MA
| |
- External RJ45 device monitors up to two 4-20mA analog sensors
- Supports ISA Type 2, ISA Type 3, and ISA Type 4 sensors
- Provides 18VDC, 25mA for each sensor
- Connector: Screw Terminal, 8-position.
- Supports CAT5/5e/6 cable up to 305 meters (not included)
- Includes Mounting Hardware
- Powered by ENVIROMUX-SEMS-16.
- Regulatory approvals: RoHS.